To change the calibration setting:
- To access calibration mode, turn the power to the gauge on with the
CAL wire grounded. The CAL wire is the GREEN wire on Pin 3 of
Connector 2 (see Fig 1 on SCX Instructions).
- The pointer will stop at 50% scale to indicate you have
successfully accessed calibration mode.
- Once the pointer stops at 50% scale remove the CAL wire from
the ground source. The pointer will move to indicate the current
calibration setting per "Calibration Settings" below.
- To change the calibration setting, momentarily ground the CAL wire.
Each time you momentarily ground the CAL wire, the calibration
setting will change.
- When the desired calibration setting is obtained, leave
the CAL wire ungrounded for 5 seconds. The gauge will save the
new calibration setting, exit calibration mode and return to normal
operating mode.
Calibration Settings
- Vac/Boost with transducer (0.5-4.5V Output): 20% scale (12" Vac)
- Volts, 8-18V: 0% scale (8V)
- Oil Pressure with 9200 sender: 100% scale (100 PSI)
- Water Temperature 100-260F with 9201 sender: 88% scale (240F)