How do I stop my SCX gauge lighting from blinking?

Problem: SCX stepper motor gauge backlight blinks periodically.

Cause: Vehicle's computer sends diagnostic pulses through its lighting circuit. The diagnostic pulses interrupt the 12V supply to the gauge LED light circuit causing the gauges to blink ON/OFF periodically.

Fix: Install a 12V relay between the light circuit and the gauge lighting wire. This will isolate the diagnostic pulses and provide a steady uninterupted 12V power to the gauge lighting circuit.